Well eXact® EZ Photometer Starter Kit — kit contents

Well eXact® EZ Photometer Starter Kit

SKU: 486203-K

Your meter

Well eXact EZ486203

Compare all package contents
Price
Regular price $401.00
Regular price Sale price $401.00
Save
/
  • In stock, ready to ship
Shipping calculated at checkout.

Delivery costs shown at checkout. Import charges may apply.

Batteries are not included with international orders.

Test chemistry, delivered differently.

eXact reagent strips deliver the test chemistry into your water sample. The Well EZ photometer measures the reaction and displays a numerical result on the meter.

Prepare your sample

Select the test on your Well EZ, fill the cell and zero the meter as instructed.

Add the right reagent

Use the specified eXact reagent and follow its dosing instructions.

Follow the test timing

Complete the mixing, reaction and reading sequence for your selected method.

Read the result

Read the numerical result directly on the meter, then rinse and clean the sample cell.

Some tests need preparation or more than one reagent. Follow the complete iron and hardness methods, and use each method’s own mixing and reaction times.

Well EZ instructions · English PDF · 2019 edition

The right test. The right reagent.

Well eXact® EZ Photometer · 486203

Measure total alkalinity, total hardness, total iron, nitrate and pH. Choose the exact Well EZ method and reagent for each test, then compare the supplied package contents.

Parameter or supplySupply roleReagent code and reference
Total alkalinity Reagent reference 486641
Method notes

If the result is HI, follow the complete range-extender method using 486665.

Exact 486203 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit.

Source reference (English PDF) · R111319-WEZQG

High-range total hardness Reagent reference 486656
Method notes

Check sample pH and alkalinity first. Conditioner 486666 may be required. Follow the full Well EZ conditioning instructions.

Exact 486203 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit.

Procedure detail to confirm: Check sample pH and alkalinity. Exact 200/220 ppm threshold remains unresolved; do not infer a numerical threshold.

Source reference (English PDF) · R111319-WEZQG

Total iron Reagent reference 486650
Method notes

Use both the iron strip and EZ Open reducer powder. Follow the complete reducer and TPTZ-strip sequence for Well EZ.

Exact 486203 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit.

Source reference (English PDF) · R111319-WEZQG

Nitrate Reagent reference 486655
Method notes

The result is nitrate as NO3. Allow the full reaction countdown before reading, following the Well EZ method.

Exact 486203 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit.

Source reference (English PDF) · R111319-WEZQG

pH Reagent reference 486639-II
Method notes

Use pH-II reagent 486639-II and the Well EZ pH method. This is a photometer reagent, not a separate pH+ instrument.

Exact 486203 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit.

Source reference (English PDF) · R111319-WEZQG

Total alkalinity Conditional range extender 486665
Method notes

Range extender for the 486641 alkalinity test when the meter reads HI. Use it only with the full Well EZ calculation procedure.

Exact 486203 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit.

Source reference (English PDF) · R111319-WEZQG

High-range total hardness Conditional preparation reagent 486666
Method notes

Conditioning reagent used with 486656 for high-alkalinity samples. Check sample pH and follow the full Well EZ conditioning instructions.

Exact 486203 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit.

Procedure detail to confirm: Supporting conditioner for the high-range total-hardness procedure. Exact 200/220 ppm threshold remains unresolved.

Source reference (English PDF) · R111319-WEZQG

Well-water reagent refill box Reagent refill pack 486212
Method notes

A refill selection for the five Well EZ parameters. Check the pack contents and each method for required reducer or conditioning reagents.

Exact 486203 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit.

Source reference (English PDF) · R111319-WEZQG

Supporting reagents and refill packs are listed alongside test reagents. Check the notes and the complete manual before ordering.

The linked guide is for Well eXact EZ, product code 486203, revision R111319-WEZQG. These five measurements describe selected aspects of water quality; they do not establish drinking-water safety or replace a full laboratory analysis.

Find your Well EZ package.

Choose the photometer with starter reagents, the Starter Kit or the Professional Kit. The Professional Kit includes a separate eXact pH+ instrument with its own calibration and probe-care requirements.

Well eXact EZ

Meter model 486203

Five well-water measurements with results on the meter. Choose the photometer with starter reagents, the Starter Kit or the Professional Kit with a separate pH+ instrument.

Starter Kit

Product code 486203-K

  • Well eXact EZ photometer with carry case
  • pH II, total iron and nitrate reagents
  • Alkalinity and high-range hardness reagents
  • Cleaning brush and instructions

Professional Kit

Product code 486203-K2

  • Well eXact EZ plus separate eXact pH+ meter
  • Well-water reagent selection and carry case
  • One pouch each of pH 4 and pH 7 buffer
  • Cleaning brush and instructions

Check the named contents of the package you choose. Some tests use more than one reagent or a preceding test, so reagent pack capacities should not be added together as a total number of water tests.

Practical support for your meter.

Factory-calibrated photometer

The Well EZ is factory-calibrated. Zero the sample, clean the cell and carry out verification as instructed. This photometer claim does not apply to the separate pH+ instrument in the Professional Kit.

Read the operating instructions

Two-year photometer warranty

Two-year limited manufacturer warranty on the Well EZ photometer, with registration within 30 days of purchase and subject to the published terms. Other instruments and replaceable probes have their own terms.

Read the manufacturer’s terms

Help with your next test

Get help choosing a kit, matching a replacement reagent or using your meter. Your product code is included when you contact ITS Europe.

Ask a product specialist

Included meter: Well eXact® EZ Photometer. The specifications and resources below refer to this instrument.

Technical specifications
Primary instrumentWell eXact EZ, product code 486203
ParametersTotal alkalinity, total hardness, total iron, nitrate and pH
Sample cellBuilt-in 4 mL cell
Light source525 nm
MemoryLast 20 results for each of five test menus
PowerFour AAA batteries, not included
DisplayResults shown on the photometer; no app required
IP ratingIP67; secure the battery base and follow care instructions

Applications

Drinking water · Well water

Manuals and downloads

Reagents for this meter

Find a specific reagent
ITS Europe eXact® Strip Micro Total Hardness High Range

High-range total hardness

eXact® Strip Micro Total Hardness High Range

Product code 486656

For Well eXact® EZ Photometer

Exact 486203 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit.

Method note: Check sample pH and alkalinity first. Conditioner 486666 may be required. Follow the full Well EZ conditioning instructions.

Procedure detail to confirm: Check sample pH and alkalinity. Exact 200/220 ppm threshold remains unresolved; do not infer a numerical threshold.

Source reference (English PDF) · R111319-WEZQG

$27.00

ITS Europe eXact® Strip Micro Total Iron TPTZ

Total iron

eXact® Strip Micro Total Iron TPTZ

Product code 486650

For Well eXact® EZ Photometer

Exact 486203 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit.

Method note: Use both the iron strip and EZ Open reducer powder. Follow the complete reducer and TPTZ-strip sequence for Well EZ.

Source reference (English PDF) · R111319-WEZQG

$29.00

Description

Keep your Well eXact EZ photometer and well-water reagents together in a foam-lined carry case. The Starter Kit combines the meter with the five-parameter reagent selection, brush and instructions.

What is included

  • Well eXact EZ photometer
  • Navy blue plastic carry case with foam insert
  • Reagents for 25 tests of each: pH II, total iron, nitrate, total alkalinity and high-range total hardness
  • Cleaning brush and instruction manual

Five measurements, directly on the meter

Measure total alkalinity, total hardness, total iron, nitrate and pH. The Well EZ displays the result on its screen, so a phone or app is not required for these tests.

How the reagent system works

eXact Strip Micro technology delivers reagent into the water sample for the photometer to measure. Use the specified reagent and follow the complete method for each parameter. Some tests need additional preparation or reagents, and reaction times vary.

Prepare for your first test

The Well EZ uses four AAA batteries, which are not included. Its built-in sample cell holds 4 mL. Zero the sample as instructed, keep the cell clean and use the correct eXact method and reagent for each measurement.

These five measurements help you understand selected aspects of well-water quality. They do not establish drinking-water safety or replace a full laboratory analysis.

Instructions and support

Well eXact EZ instruction manual, revision R111319-WEZQG (PDF)

Earlier Well eXact EZ instruction manual, 2017 edition (PDF)

You may also like