Spa eXact® EZ Photometer Starter Kit
Your meter
Spa EZ486202
- In stock, ready to ship
Delivery costs shown at checkout. Import charges may apply.
Batteries are not included with international orders.
Your meter
Spa EZ486202
Delivery costs shown at checkout. Import charges may apply.
Batteries are not included with international orders.
eXact reagent strips deliver the test chemistry into your water sample. The Spa EZ photometer measures the reaction and displays a numerical result on the meter.
Select the test on your Spa EZ, fill the cell and zero the meter as instructed.
Use the specified eXact reagent and follow its dosing instructions.
Complete the mixing, reaction and reading sequence for your selected method.
Read the numerical result directly on the meter, then rinse and clean the sample cell.
Combined chlorine follows free chlorine on the same sample. Follow the full Spa EZ sequence for combined and total chlorine, including any additional reagent or calculation. Timing varies by method.
Spa EZ instructions · English PDF · 2023 editionSpa eXact® EZ Photometer · 486202
Explore the seven parameters supported by Spa EZ, then choose the matching reagent for your test. The supplied reagent selection depends on the package.
| Parameter or supply | Supply role | Reagent code and reference |
|---|---|---|
| Total alkalinity | Reagent reference |
486641
Method notesStart with 486641. If the result is HI, retain the sample and use 486665 as the Spa EZ instructions direct, adding 130 ppm per extender strip to the final displayed value. Exact 486202 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit. |
| Total alkalinity | Conditional range extender |
486665
Method notesUse with 486641 after an HI total alkalinity result on the retained sample. Follow Spa EZ steps 5–7 and add 130 ppm per extender strip. This is an additional reagent, not a standalone alkalinity test. Exact 486202 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit. |
| Total bromine | Reagent reference |
486644
Method notesUse reagent 486644 with the Spa EZ bR(1) method. Follow the Spa EZ timing and interference guidance. Exact 486202 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit. |
| Calcium hardness | Reagent reference |
486629
Method notesFollow the Spa EZ CA(5) method, including the automatic 20-second reaction period after the strip is removed. This measures calcium hardness. Exact 486202 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit. |
| Free chlorine | Reagent reference |
486637
Method notesRetain this sample if you also need combined or total chlorine, then continue with DPD-3 reagent 486638 using the Spa EZ sequence. Exact 486202 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit. |
| Combined and total chlorine | Reagent reference |
486638
Method notesRun free chlorine with DPD-1 reagent 486637 first on the same sample. Re-zero, use DPD-3 and read combined chlorine, then press READ again for total chlorine. If a second DPD-1 strip was used above 6 ppm, calculate total chlorine manually as instructed. Exact 486202 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit. |
| pH | Reagent reference |
486639-II
Method notesUse pH-II reagent 486639-II. Test pH before chlorine, or thoroughly clean the sample cell before testing pH after chlorine. Exact 486202 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit. |
| Spa refill box | Reagent refill pack |
486215
Method notesSix-reagent refill selection for Spa EZ: alkalinity, pH, calcium hardness, bromine, free chlorine and combined chlorine. Total chlorine follows the complete DPD-1 then DPD-3 sequence. Test capacities vary by reagent. No photometer is included. Exact 486202 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit. |
No reagent references match your search. Try a parameter or product code, or clear the search.
Supporting reagents and refill packs are listed alongside test reagents. Check the notes and the complete manual before ordering.
The linked 2023 guide is for Spa eXact EZ, product code 486202. Follow this model’s complete instructions when matching a method or refill. The earlier 2017 guide remains available in the product documentation.
Choose the photometer with starter reagents, the Starter Kit or the Professional Kit. The Professional Kit includes a separate eXact pH+ instrument with its own calibration and probe-care requirements.
Standalone spa photometer with starter-reagent, Starter Kit and Professional Kit options. The Professional Kit includes a separate pH+ instrument.
Product code 486202
Product code 486202-K
Product code 486202-K2
Check the named contents of the package you choose. Some tests use more than one reagent or a preceding test, so reagent pack capacities should not be added together as a total number of water tests.
The Spa EZ photometer is factory-calibrated for its specified methods. Zero each sample, keep the cell clean and use the verification checks described in the instructions. The separate pH+ instrument in the Professional Kit has its own calibration requirements.
Read the operating instructionsTwo-year limited manufacturer warranty on the photometer. Registration within 30 days and the manufacturer’s terms apply; other instruments and replaceable probes have their own terms.
Read the manufacturer’s termsGet help choosing a kit, matching a replacement reagent or using your meter. Your product code is included when you contact ITS Europe.
Ask a product specialistIncluded meter: Spa eXact® EZ Photometer. The specifications and resources below refer to this instrument.
| Product code | 486202 |
|---|---|
| Supported parameters | 7, including combined and total chlorine using the complete test sequence |
| Reading | Results on the meter; no phone or app required for Spa EZ measurements |
| Optical system | 525 nm light source; 11 mm path length |
| Sample cell | Built-in 4 mL cell |
| IP rating | IP67; fit the battery base and seal as instructed |
| Power | Four AAA batteries, not included |
| Instruction reference | Spa eXact EZ Quick Start Guide, revision 062923-SEZQG (2023) |
Pools & spas
Total alkalinity
Product code 486641
For Spa eXact® EZ Photometer
Exact 486202 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit.
Method note: Start with 486641. If the result is HI, retain the sample and use 486665 as the Spa EZ instructions direct, adding 130 ppm per extender strip to the final displayed value.
Source reference (English PDF) · 062923-SEZQG
$21.00
Total alkalinity
Conditional range extender
Product code 486665
For Spa eXact® EZ Photometer
Exact 486202 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit.
Method note: Use with 486641 after an HI total alkalinity result on the retained sample. Follow Spa EZ steps 5–7 and add 130 ppm per extender strip. This is an additional reagent, not a standalone alkalinity test.
Source reference (English PDF) · 062923-SEZQG
$27.00
Total bromine
Product code 486644
For Spa eXact® EZ Photometer
Exact 486202 photometer and cited manual revision. The source states no serial or firmware boundary. This does not cover a separate pH+ instrument in a kit.
Method note: Use reagent 486644 with the Spa EZ bR(1) method. Follow the Spa EZ timing and interference guidance.
Source reference (English PDF) · 062923-SEZQG
$21.00
A Spa eXact EZ photometer, carrying case and reagent selection for regular hot tub and spa testing. Compare the supplied contents with the Professional Kit if you also need a separate pH+ instrument.
Follow the complete test method. Some results require a preceding test or more than one reagent, so the reagent pack capacities should not be added together as a total number of water tests.
Measure total alkalinity, total bromine, calcium hardness, free chlorine, combined chlorine, total chlorine and pH using the specified Spa EZ methods and reagents.
The combined chlorine test follows the free chlorine test on the same sample. Follow the complete sequence in the instructions for combined and total chlorine, including any additional reagent or calculation required.
Spa EZ uses factory calibration for its specified eXact reagents. Zero the sample, keep the cell clean and carry out verification checks as instructed. The reagent strip delivers the test chemistry into the water for the photometer to measure.
Read the result directly on the meter. A phone or app is not needed for Spa EZ measurements. Four AAA batteries are required and are not included.
The current NSF/ANSI 50 listing gives L1 for free chlorine, combined chlorine and total bromine, and L2 for pH, for Spa/Hot Tub use. Certification applies to marked products and their corresponding reagents. View the independent NSF listing.
The Spa EZ photometer has a two-year limited manufacturer warranty, subject to its terms, including registration within 30 days of purchase. Other instruments and replaceable probes have their own terms. Read the photometer warranty.
Spa eXact EZ instructions: English PDF, 2023 edition
Earlier Spa eXact EZ instructions: English PDF, 2017 edition
Find Spa EZ reagents · Ask a product specialist about this package