eXact® Micro 20 Bluetooth Photometer

SKU: 486700-BT

The Micro 20 Bluetooth photometer combines dual-wavelength measurement with more than forty pre-programmed parameters. Record and share test results through the eXact iDip app when your workflow needs a digital history.

Parameters
Total alkalinity, Aluminium, Ammonia, Biguanide…

Your meter

Micro 20 Bluetooth486700-BT

Compare all package contents
Price
Regular price
£719.99
Regular price Sale price
£719.99
Save
/
  • In stock, ready to ship
Tax included. Shipping calculated at checkout.

Free UK standard delivery. In-stock orders dispatched within 3–5 working days.

Test chemistry, delivered differently.

eXact reagent strips deliver the test chemistry into your water sample. The Micro 20 photometer measures the reaction and displays a numerical result on the meter.

Prepare your sample

Select the test on your Micro 20, fill the sample cell and zero the meter as instructed.

Add the right reagent

Use the specified eXact reagent and follow its dosing instructions.

Follow the test timing

Complete the mixing, reaction and countdown steps for your test.

Read the result

Read the result directly on the meter. If connected before the test, the optional app can also record it.

Reagents, sample preparation and timing vary by test. Some methods use liquid reagents, multiple reagents or additional equipment. Follow the complete instructions for your instrument version and method.

Micro 20 v3.1 instructions · English PDF

The right test. The right reagent.

eXact® Micro 20 Bluetooth Photometer (v3.1) · 486700-BT

Explore the parameters covered by the Micro 20 photometer, then use the model-specific reagent finder to choose refills. These are not a list of tests supplied in every kit. Some methods need multiple reagents, additional equipment or a calculation, so follow the complete method and check the package contents.

Parameter or supplySupply roleReagent code and reference
Freshwater / marine / pool total alkalinity Reagent reference 486641
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Aluminium Reagent reference 486821
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Ammonia Reagent reference 486654
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Biguanide Reagent reference 486810
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Bromine Reagent reference 486644
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Calcium Reagent reference 486629
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Ultra-high marine calcium Reagent reference 486668-K
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Chloride, standard and high range Reagent reference 486757
Method notes

For the high-range method, you also need Mini Dilution Kit II (487202).

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Free chlorine Reagent reference 486637
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Total chlorine Reagent reference 486670
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Chromium(VI) Reagent reference 486614
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Copper Reagent reference 486632
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Cyanide Reagent reference 486812
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Cyanuric acid III Reagent reference 481652-III
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Fluoride Reagent reference 486643
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Ultra-high marine total hardness Reagent reference 486669-K
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

High-range total hardness Reagent reference 486656
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Low-range total hardness Reagent reference 486630
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Hydrogen peroxide Reagent reference 486648
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Total iron Reagent reference 486650
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Manganese Reagent reference 486606
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Metals (+2) Reagent reference 486604
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Molybdate Reagent reference 486653
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Freshwater / marine nitrate Reagent reference 486655
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Nitrite Reagent reference 486623
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Ozone Reagent reference 486634
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Peracetic acid Reagent reference 486675
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Permanganate Reagent reference 486626
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Freshwater / pool pH Reagent reference 486639
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Freshwater / marine BT-pH Reagent reference 486657
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Acidic pH Reagent reference 486624
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Phosphate Reagent reference 486814
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Quaternary ammonium compounds Reagent reference 486823
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Sulphate Reagent reference 486608
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Sulphide Reagent reference 486818
Method notes

Follow the complete procedure in the exact manual for this instrument and reagent.

Micro 20 Bluetooth 486700-BT v3.1; serial M20BTA00484 onwards only. Earlier serials M20BTA00001-M20BTA00483 are outside this evidence.

Source reference (English PDF) · v3.1, revision 06/04/2021

Supporting reagents and refill packs are listed alongside test reagents. Check the notes and the complete manual before ordering.

The linked v3.1 manual applies to serial numbers M20BTA00484 and above. Earlier instruments use different instructions. Check the version and serial number on your meter before choosing a method or refill. Ask us if you need help matching an older instrument.

Find your Micro 20 package.

Choose the photometer on its own or a kit for your application. The Well Driller Professional kit also includes a separate pH+ meter, with its own calibration and probe-care requirements.

Micro 20 Bluetooth

Meter model 486700-BT

Bluetooth photometer with standard, pool, marine and well-water kit options. Check each package for the supplied reagents and accessories.

Photometer package

Product code 486700-BT

  • Micro 20 Bluetooth photometer
  • Cleaning brush and instruction manual
  • Reagent bottles and carry case sold separately
  • Four AAA batteries required, not included

Pool Kit

Product code 486700-BT-KP

  • Micro 20 Bluetooth photometer with carry case
  • Pool reagent selection for chlorine and water balance
  • Additional tests include phosphate, copper and nitrate
  • Mini-dilution kit, brush and instructions

Marine Kit

Product code 486700-BTMA

  • Micro 20 Bluetooth photometer with carry case
  • Ultra-high calcium and total hardness reagent kits
  • Marine reagent selection including ammonia and pH-BT
  • Mini-dilution kit, 5 mL syringe, brush and instructions

Well Drillers Kit

Product code 486700-BT-WD

  • Micro 20 Bluetooth photometer with carry case
  • Well water reagent selection including hardness and iron
  • Includes manganese, nitrate and chlorine methods
  • Mini-dilution kit, brush and instructions

These summaries describe the current UK listings. Follow each complete test method: some tests use several reagents or a preceding test. Reagent pack capacities should not be added together as a total number of water tests.

On-meter readings. Connected records.

Use Micro 20 independently, or connect it to the eXact iDip app on a compatible phone or tablet when you want a digital record.

Read on the meter

Choose the method using the meter controls and read the result on its display. A phone is not needed to obtain the reading.

Record as you test

Connect to the app before running the test to display and save the result there. The manual also describes entering an existing result manually.

Keep and share your records

Use the app to organise results by customer and water source, then share them by email or export them for a spreadsheet.

Practical support for your meter.

Factory-calibrated photometer

Micro 20 uses fixed factory calibrations for its specified methods. Zero each sample, keep the cell clean and perform verification checks as directed. The separate pH+ instrument in the Professional kit has its own calibration requirements.

Read the operating instructions

Two-year photometer warranty

The Micro 20 photometer has a two-year limited manufacturer warranty, subject to its terms, including registration within 30 days of purchase. Other instruments and replaceable probes have their own terms.

Read the manufacturer’s terms

Help with your next test

Get help choosing a kit, matching a replacement reagent or using your meter. Your product code is included when you contact ITS Europe.

Ask a product specialist
Technical specifications
Product code486700-BT
Available parametersMore than 40 pre-programmed
Optical systemDual wavelength: 525 nm and 638 nm (v3.1)
ConnectivityBluetooth; optional eXact iDip app for digital records
Sample volume4 mL built-in sample cell (v3.1)
Water protectionManufacturer rating: exceeds IP67 (v3.1). Secure the battery cover as instructed.
PowerFour AAA batteries, not included
Specification scopeMicro 20 v3.1 manual, serial M20BTA00484 and above. Earlier instruments require their matching instructions.

Applications

Drinking water · Industrial water · Pond & aquarium · Pools & spas

App for this meter

Reagents for this meter

Find a specific reagent
Description

A dual-wavelength photometer for water testing, with results on the meter and optional Bluetooth recording through the eXact iDip app. Choose the reagents and accessories for the tests you need.

Product code: 486700-BT

Digital results, with optional app recording

The Micro 20 has pre-programmed methods for more than 40 water quality tests. Read results on the meter, or connect to the eXact iDip app before running a test to record and share the result. A smartphone is not required to read the meter. Check current app and device compatibility before using Bluetooth.

Reagent technology made for the method

eXact Strip Micro strips deliver reagent into the sample for the photometer to measure. Use the specified genuine eXact reagents and follow the method for your water sample. Some tests also need liquid or powder reagents, additional components or sample preparation.

Factory-set photometer calibration

The Micro 20 is factory calibrated. Routine user recalibration is not required, but sample zeroing, cell cleaning and the checks in the instruction manual remain part of correct use. Calibration verification is a check of the meter, rather than an adjustment.

What is included

  • eXact® Micro 20 Bluetooth® photometer
  • Cleaning brush
  • Instruction manual

Carry case and reagent bottles are not included. Select the correct reagents and any method-specific accessories separately.

The Micro 20 requires four AAA batteries, which are not included.

Warranty and support

The Micro 20 photometer has a two-year limited manufacturer warranty. Register within 30 days of purchase and follow the manufacturer's care and storage instructions. See the manufacturer's manual for the registration and warranty details.

Instructions and app

Download the Micro 20 v3.1 manual, revision June 2021. This manual applies to serial numbers M20BTA00484 onwards. For an earlier serial number, use the instructions for that instrument version.

eXact iDip for iPhone and iPad · eXact iDip for Android. Connect before running a test to send its result to the app, or enter a reading manually.

You may also like